"Characterisation of chosen parameters"

Characterisation of chosen parameters

$f_{T} vs I_{D}$

Next is obtaining a plot of $f_{T} vs I_{D}$. Therefore the $f_{T}$ testbench is used using the obtained values for $V_{D}, M, L$ and running the simulation from $0mA$ to $6.4mA$. Now adding the $100\Omega$ load in series with $V_{D}$ and running the simulation gives the following plot for $f_{T}$.

The $f_{T}$ versus the $I_{D}$
Figure: FtIdPlot.svg
The $f_{T}$ versus the $I_{D}$

$g_{m}$

Next is plotting the $g_{m}$, therefore the $g_{m}$ testbench is used where all values of the previous parts of the assignment have been substituted. And the $100 \Omega$ load is connected. Now plotting $g_{m} vs I_{D}$ gives the following result:

The $g_{m}$ versus the $I_{D}$
Figure: gmPlot.svg
The $g_{m}$ versus the $I_{D}$

Measuring the $g_m$ at $I_D = 6.4 mA$ gives approximately $g_m = 94 mS$.

Go to Assignment-1---Drive-Capability-CS-stage_index

SLiCAP: Symbolic Linear Circuit Analysis Program, Version 1.0 © 2009-2021 SLiCAP development team

For documentation, examples, support, updates and courses please visit: analog-electronics.eu

Last project update: 2022-01-13 18:09:51